Workers in electrical maintenance, power generation, construction and manufacturing may face head injury risks alongside electrical hazards. Selecting the wrong helmet can leave workers without the intended level of protection.

Industrial safety helmets are available in different electrical classifications under the ANSI/ISEA Z89.1 standard. These include Class G, Class E and Class C. Each class has a different purpose and electrical performance requirement.

A Class G safety helmet is designed for general use and tested for electrical performance at 2,200 volts. A Class E helmet is tested at 20,000 volts. A Class C helmet provides impact protection but does not provide electrical protection.

These test voltages are not safe working voltage ratings. They describe the standard’s proof-test conditions, not the voltage at which a worker can safely contact an electrical conductor.

For Indian buyers, another distinction matters. IS 2925:1984 is the Indian Standard reference for industrial safety helmets. The Class G, E and C labels belong to the ANSI/ISEA classification system. Buyers should check the exact standard and certification applicable to each helmet.

This guide explains the differences, applications, limitations and selection factors for electrical safety helmets.

Key Takeaways

  • Class G, Class E and Class C are electrical classifications under ANSI/ISEA Z89.1.
  • A Class G safety helmet is proof-tested at 2,200 volts under the ANSI classification.
  • A Class E safety helmet is proof-tested at 20,000 volts under the ANSI classification.
  • A Class C safety helmet does not provide electrical protection.
  • Proof-test voltage must not be treated as a safe working voltage.
  • Indian buyers should distinguish ANSI electrical classes from BIS certification under IS 2925.

What Are Class G, Class E and Class C Safety Helmets?

Class G, Class E and Class C are electrical performance classifications for industrial protective helmets under ANSI/ISEA Z89.1. They indicate how the helmet is tested for electrical insulation and whether it is intended for use around electrical hazards.

The three classes serve different workplace requirements:

  • Class G (General): Intended to reduce the danger of contact with low-voltage electrical conductors.
  • Class E (Electrical): Intended to reduce the danger of contact with higher-voltage electrical conductors.
  • Class C (Conductive): Intended for impact protection without electrical insulation.

The classification helps employers identify a helmet’s electrical performance. However, it does not replace an electrical risk assessment or safe work procedures.

A helmet’s electrical class is also separate from its impact type. ANSI/ISEA Z89.1 uses Type I and Type II designations for impact protection. Type I addresses impact to the top of the head, while Type II includes top and lateral impact requirements.

Therefore, a helmet can have both an impact type and an electrical class. For example, a helmet may be marked Type I, Class E.

What Is a Class G Safety Helmet?

A Class G safety helmet is an industrial protective helmet designed to reduce the danger of contact with low-voltage electrical conductors. Under ANSI/ISEA Z89.1, test samples are proof-tested at 2,200 volts, phase to ground.

Class G stands for General. It is intended for workplaces where workers need head protection and a defined level of electrical performance.

Electrical Performance of Class G Helmets

The ANSI classification specifies a proof-test voltage of 2,200 volts for Class G helmets.

This figure is a test condition. It does not mean that a worker can safely work on or touch a 2,200-volt electrical system while wearing the helmet.

The helmet must be used within its certified application and the manufacturer’s stated limitations. Electrical safety also depends on the task, exposure, other PPE and work controls.

Where Are Class G Safety Helmets Used?

Class G helmets may be considered for workplaces with general industrial hazards and certain low-voltage electrical exposure, subject to the applicable risk assessment.

Common application areas include:

  • General industrial maintenance.
  • Manufacturing facilities.
  • Construction sites with electrical equipment.
  • Warehouses and logistics facilities.
  • Certain utility and maintenance activities.
  • Industrial operations where low-voltage electrical hazards are identified.

For example, a maintenance worker in a manufacturing facility may work near electrical equipment while also facing impact hazards from overhead structures. The safety team should assess the electrical exposure and specify a helmet with the appropriate certification.

When Should You Choose a Class G Helmet?

Consider a Class G helmet when the workplace assessment identifies a need for industrial head protection and the relevant electrical exposure falls within the helmet’s intended application.

Before selection, verify the helmet’s ANSI marking, manufacturer documentation and compatibility with other PPE.

Do not select Class G solely because a supplier describes it as an electrical helmet. Confirm the actual certification and limitations.

What Is a Class E Safety Helmet?

A Class E safety helmet is an industrial protective helmet designed to reduce the danger of contact with higher-voltage electrical conductors. Under ANSI/ISEA Z89.1, test samples are proof-tested at 20,000 volts, phase to ground.

Class E stands for Electrical. It is intended for applications where electrical hazards require the higher electrical performance classification.

Electrical Performance of Class E Helmets

The ANSI/ISEA classification specifies a proof-test voltage of 20,000 volts for Class E helmets.

This is a laboratory proof-test condition. It is not a statement that a worker can safely approach, touch or work on a 20,000-volt conductor.

Employers must follow electrical safety procedures, determine safe approach distances and provide all required electrical PPE. A helmet alone cannot protect a worker from every electrical hazard.

Where Are Class E Safety Helmets Used?

Class E helmets may be suitable for applications where workers face higher-voltage electrical hazards and the risk assessment requires this classification.

Potential application areas include:

  • Electrical utility operations.
  • Power generation facilities.
  • Electrical substations.
  • High-voltage maintenance environments.
  • Industrial electrical installations.
  • Certain transmission and distribution activities.

The exact helmet specification depends on the electrical system, task and applicable safety requirements.

When Should You Choose a Class E Helmet?

Consider a Class E helmet when the risk assessment identifies higher-voltage electrical exposure and the helmet’s certification matches the required application.

Before procurement, confirm:

  • The ANSI/ISEA standard edition and class marking.
  • The manufacturer’s electrical test documentation.
  • The helmet’s intended use and limitations.
  • Compatibility with other electrical PPE.
  • Inspection, storage and replacement instructions.

Do not treat a Class E helmet as permission to work on energised equipment. Electrical isolation, approved procedures and task-specific protection remain essential.

What Is a Class C Safety Helmet?

A Class C safety helmet is designed to provide impact protection but does not provide electrical insulation under the ANSI/ISEA classification. Class C stands for Conductive.

It may be considered for workplaces where head impact hazards exist but electrical protection is not required from the helmet.

Electrical Performance of Class C Helmets

Class C helmets are not intended to protect against contact with electrical conductors.

They should not be selected for work where the wearer may be exposed to electrical contact hazards requiring an electrically rated helmet.

Some Class C models use ventilation features to support airflow. However, ventilation alone does not define the class. The manufacturer’s certification and markings determine the helmet’s classification.

Where Are Class C Safety Helmets Used?

Class C helmets may be considered in environments where impact protection is required and electrical hazards are not present or are adequately controlled through other measures.

Potential application areas include:

  • Certain warehouse operations.
  • General maintenance activities away from electrical exposure.
  • Selected manufacturing tasks.
  • Work areas where ventilation is a design consideration.
  • Applications where the risk assessment does not require electrical insulation.

A Class C helmet should not be used near exposed electrical conductors when electrical protection is required.

When Should You Avoid a Class C Helmet?

Avoid Class C helmets where workers may face electrical contact hazards.

For example, a worker carrying out electrical maintenance near exposed conductors should not use a Class C helmet when the task requires an electrically rated helmet.

The employer should select the correct electrical class based on the risk assessment and applicable requirements.

Class G vs Class E vs Class C Safety Helmets: Key Differences

The main difference between Class G, Class E and Class C helmets is their electrical performance classification under ANSI/ISEA Z89.1.

Comparison factorClass GClass EClass C
Full formGeneralElectricalConductive
Electrical protectionIntended for lower-voltage conductor contact hazardsIntended for higher-voltage conductor contact hazardsNo electrical protection
ANSI proof-test voltage2,200 V, phase to ground20,000 V, phase to groundNo electrical proof-test rating
Typical selection contextGeneral industrial work with specified electrical exposureWork requiring the higher electrical classWork where electrical insulation is not required
Suitable for electrical hazards?Subject to its intended classification and risk assessmentSubject to its intended classification and risk assessmentNo
Impact protectionDepends on helmet type and certificationDepends on helmet type and certificationDepends on helmet type and certification

The table summarises ANSI electrical classes. It does not establish a safe working voltage for any helmet.

The proof-test figures must not be used to determine approach distances or permission to work on live equipment. Follow the applicable electrical safety rules and manufacturer instructions.

What Is the Difference Between Helmet Electrical Class and Impact Type?

Electrical class and impact type describe two different performance characteristics. The electrical class concerns electrical insulation, while the impact type concerns the direction of impact protection.

Under ANSI/ISEA Z89.1, helmets use two impact types.

Type I Helmets

Type I helmets are intended to reduce the force of impact resulting from a blow to the top of the head.

They are relevant where the main impact risk comes from objects falling onto the top of the helmet.

Type II Helmets

Type II helmets are intended to reduce the force of impact from blows to the top and sides of the head.

They include additional lateral impact performance requirements.

How Do Type and Class Work Together?

A helmet’s type and class should be read together.

For example:

  • Type I, Class G: Top-impact protection with Class G electrical classification.
  • Type II, Class E: Top and lateral impact protection with Class E electrical classification.
  • Type I, Class C: Top-impact protection without electrical insulation.

The correct combination depends on the workplace hazard assessment. Do not assume that every helmet within one electrical class has the same impact performance.

Which Safety Helmet Class Is Best for Electrical Work?

The correct electrical safety helmet class depends on the voltage exposure, task and risk assessment. Class G and Class E are the ANSI classifications intended for different electrical exposure conditions, while Class C does not provide electrical protection.

Use the following considerations when specifying a helmet.

For General Industrial and Lower-Voltage Exposure

Class G may be considered where the risk assessment identifies the need for the relevant lower-voltage electrical classification.

Confirm the helmet’s certification and intended application before use.

For Higher-Voltage Electrical Exposure

Class E may be considered where the task requires the higher electrical class under ANSI/ISEA Z89.1.

The helmet must form part of a complete electrical PPE arrangement. It does not replace electrical isolation, insulated tools, protective clothing or other required controls.

For Work Without Electrical Exposure

Class C may be considered where impact protection is needed but electrical insulation is not required.

If electrical exposure may occur, reassess the task before choosing a Class C helmet.

What Safety Helmet Standards Apply in India?

Indian buyers should distinguish the ANSI/ISEA electrical classes from Indian industrial helmet requirements. IS 2925:1984 is the Indian Standard reference for industrial safety helmets.

IS 2925:1984: Industrial Safety Helmets

IS 2925:1984 specifies requirements for industrial safety helmets in India. The standard addresses aspects of helmet construction and performance, including impact and penetration resistance.

BIS certification and product documentation should be checked when purchasing helmets for Indian industrial workplaces.

The Class G, Class E and Class C labels are ANSI/ISEA electrical classifications. They should not be presented as the three classes under IS 2925.

ANSI/ISEA Z89.1: Industrial Head Protection

ANSI/ISEA Z89.1 is the American standard for industrial head protection. It classifies helmets by impact type and electrical class.

The electrical classes are:

  • Class G: General.
  • Class E: Electrical.
  • Class C: Conductive.

A helmet marked with an ANSI class should have supporting conformity information for the relevant standard edition.

What Should Indian Buyers Verify?

When purchasing an electrical safety helmet in India, check the following:

  1. Applicable standard: Confirm whether the product is certified to IS 2925, ANSI/ISEA Z89.1 or another specified standard.
  2. Electrical class: If the product claims Class G or Class E, verify the ANSI classification and supporting documents.
  3. Impact type: Check whether the helmet is Type I or Type II where ANSI classification applies.
  4. Product markings: Review the manufacturer, model, standard, class and other required markings.
  5. Certification documents: Request current test reports and relevant certificates.
  6. Intended application: Confirm that the product is suitable for the work environment.
  7. Manufacturer instructions: Review fitting, inspection, storage and replacement requirements.

Do not assume that an ISI mark automatically means a helmet is Class G or Class E. Likewise, an ANSI Class E marking should not automatically be treated as proof of BIS certification.

How Do You Select the Right Electrical Safety Helmet?

The right electrical safety helmet should match the electrical risk, impact hazard, applicable standard and worker’s PPE requirements. Procurement teams should confirm these factors before approving a model.

1. Identify Electrical Exposure

Determine whether workers may come into contact with electrical conductors or work near equipment that creates electrical exposure.

Record the nature of the task, system conditions and potential contact hazards. A qualified electrical safety professional should help determine the required controls.

2. Assess the Impact Hazard

Electrical classification does not describe every aspect of impact protection.

Identify whether workers face top-impact hazards, lateral impact hazards or both. Use the helmet’s impact type and certification to match the identified risk.

3. Verify the Helmet’s Electrical Class

If the specification requires Class G or Class E, check the actual helmet marking and supporting documentation.

Do not rely on a product title, colour or supplier description alone.

4. Check Compatibility With Other PPE

Electrical workers may also need eye protection, hearing protection, face shields, insulated gloves and other task-specific PPE.

Confirm that the helmet supports the required accessories and does not interfere with their fit or performance.

5. Check Fit and Retention

A helmet should fit securely and remain correctly positioned during normal work.

Adjust the suspension according to the manufacturer’s instructions. Where a chin strap is supplied and required, use the approved arrangement.

6. Review Environmental Conditions

Consider heat, sunlight, moisture, dust and chemical exposure.

Check the manufacturer’s instructions for material limitations, cleaning agents and storage conditions. Some substances can affect helmet materials.

7. Verify Certification and Documentation

Before placing a bulk order, obtain the relevant technical documents.

The documents should identify the standard, model, electrical class where applicable, impact type, limitations and maintenance instructions.

How Should Class G, Class E and Class C Helmets Be Inspected?

Inspect helmets before use and follow the manufacturer’s maintenance schedule. Electrical classification does not remove the need for regular inspection.

Workers should check:

  • The shell for cracks, dents or deformation.
  • The suspension for damage or missing components.
  • The headband and adjustment mechanism.
  • The chin strap and attachments, where fitted.
  • The helmet markings and identification.
  • Signs of exposure to chemicals, heat or other damaging conditions.
  • Any unauthorised modifications or accessories.

A helmet with visible damage should be removed from service. Follow the manufacturer’s instructions after an impact event or suspected electrical exposure.

Do not drill holes, cut the shell, paint the helmet or attach unapproved accessories. Such changes may affect the helmet’s performance and electrical properties.

Store helmets in the conditions specified by the manufacturer. Avoid storage conditions that may cause deterioration.

Common Mistakes When Selecting Electrical Safety Helmets

Incorrect classification and assumptions about voltage ratings can create serious risks. Employers should address these mistakes during procurement and worker training.

Treating Proof-Test Voltage as Safe Working Voltage

The 2,200 V and 20,000 V figures are ANSI proof-test conditions. They are not safe working voltage limits.

Never use these numbers to decide whether a worker can touch an energised conductor.

Using Class C Near Electrical Hazards

Class C helmets do not provide electrical protection.

Do not select them for tasks where the risk assessment requires an electrically rated helmet.

Confusing ANSI Classes With Indian Standards

Class G, Class E and Class C belong to ANSI/ISEA Z89.1. IS 2925:1984 is the Indian industrial safety helmet standard.

Buyers should check the exact certification rather than treating these labels as interchangeable.

Ignoring Impact Type

A helmet’s electrical class does not establish its impact type.

Check whether Type I or Type II protection is needed for the work activity.

Relying on Helmet Colour

Helmet colour does not establish electrical classification.

Verify the markings and technical documentation.

Using a Damaged Helmet

Cracks, damaged suspension components and unauthorised modifications can affect performance.

Remove questionable helmets from service and follow the manufacturer’s replacement guidance.

Frequently Asked Questions

What is a Class G safety helmet?

A Class G safety helmet is an ANSI/ISEA industrial helmet intended to reduce the danger of contact with low-voltage electrical conductors. Its test samples are proof-tested at 2,200 volts, phase to ground. This is a test voltage, not a safe working voltage.

What is a Class E safety helmet?

A Class E safety helmet is intended to reduce the danger of contact with higher-voltage electrical conductors. Under ANSI/ISEA Z89.1, its test samples are proof-tested at 20,000 volts, phase to ground. Workers must still follow electrical safety procedures and use all required PPE.

What is a Class C safety helmet?

A Class C safety helmet provides impact protection but does not provide electrical insulation under ANSI/ISEA Z89.1. It may be considered for workplaces where electrical protection is not required from the helmet. It should not be used where electrical contact hazards require an electrically rated helmet.

What is the difference between Class G and Class E helmets?

Class G helmets are proof-tested at 2,200 volts, while Class E helmets are proof-tested at 20,000 volts under ANSI/ISEA Z89.1. They are intended for different electrical exposure conditions. These figures are test voltages, not safe working voltage ratings.

Is Class E better than Class G?

Class E has the higher electrical proof-test requirement under ANSI/ISEA Z89.1. However, the correct choice depends on the workplace risk assessment and required certification. A higher classification does not replace electrical safety procedures.

Can a Class C helmet be used for electrical work?

A Class C helmet does not provide electrical protection under the ANSI classification. It should not be selected where the task requires an electrically rated helmet. Choose the appropriate electrical class based on the hazard assessment.

Are Class G, Class E and Class C Indian safety helmet classifications?

No. These electrical classes belong to ANSI/ISEA Z89.1. IS 2925:1984 is the Indian Standard reference for industrial safety helmets. Buyers in India should verify the exact standard and certification applicable to the product.

Does a Class E helmet protect workers from 20,000 volts?

The 20,000-volt figure is the ANSI proof-test voltage for Class E test samples. It is not a declaration that a worker can safely work on or contact a 20,000-volt conductor. Follow electrical safety rules and the manufacturer’s instructions.

What is the difference between Type I and Type II helmets?

Type I helmets are designed for impact to the top of the head. Type II helmets include requirements for impact to the top and sides of the head. These impact types are separate from the electrical classes.

How do I verify an electrical safety helmet’s classification?

Check the helmet’s permanent markings, model information and manufacturer documentation. Verify the ANSI/ISEA standard edition and the stated electrical class. For Indian procurement, also confirm any required BIS certification and applicable product requirements.

Conclusion

Class G, Class E and Class C safety helmets serve different electrical protection requirements under ANSI/ISEA Z89.1. Class G helmets are proof-tested at 2,200 volts, Class E helmets at 20,000 volts, and Class C helmets provide no electrical protection.

These proof-test figures must never be treated as safe working voltage limits. The correct helmet depends on the electrical exposure, impact hazards, work activity and applicable certification.

For Indian organisations, it is important to distinguish ANSI electrical classes from IS 2925:1984. Procurement teams should verify the product’s markings, certification documents, intended application and manufacturer instructions before purchase.

A suitable electrical safety helmet is only one part of a complete workplace safety programme. Risk assessment, electrical isolation, safe work procedures, training and compatible PPE remain essential.

Need Help Reviewing Your Workplace Safety Requirements?

Selecting suitable PPE requires an understanding of the hazards, work conditions and applicable standards. Indian Inovatix Ltd., Ahmedabad, Gujarat, India, manufactures fall protection and height safety equipment for industrial and infrastructure applications.

Contact the team to discuss your workplace height safety requirements and the equipment needed for your project.

Call us at +91-8849452638 or write to info@indianinovatix.com to get started.

Indianinovatix

Talk to Our Safety & Protection Specialists

Have questions or need guidance? Our experts can help you choose the most reliable and high-performance safety solutions tailored to your industry and site requirements.

Need Help Determining the Right Fall Protection for You?

With our vast experience, our experts will assist you in selecting the most relevant system for your needs.

Contact Information

    Chat with Us